Hydronit Catalogue

PPC 2017/1-D160

www.hydronit.com +39 03621841210

SECTION D

CSPC15 - PROPORTIONAL FLOW CONTROL VALVE

88

Hex. 24

2

59

1

Coils

Ø 33

Supply voltage Coil code

Connector code

47

28

12DC 24DC

M6306012 KA132000B1 M6306024 KA132000B1

Hex. 19

For the controller see the VPC table in D section

3/4-16 UNF-2A

Spare part code

Assembly code

eg: T12DC T *** Voltage

CSPC

Proportional flow control valve

Main features

Nominal size: 15 = 15 l/min Option: 0 = no option

15

Max press.

210 bar

Max flow

22 l/min

Mounting cavities

0

Weight

0,1 Kg (without coil)

PWM

120Hz

0 1 2 5 6 7 8 3 4

Supply voltage: - 0000 = no coil (std)

0000

Hysteresis

5% (10% above 85% Imax)

- 12DC - 24DC see coils table

Duty cycle

ED 100%

Voltage

+/- 10% nominal voltage

Note: cavities 3, 4 and 6 are present on central manifold type UB only.

EN50081-1/EN50082-2 (89/336 CEE) 73/23/CEE / 96/68/CEE

Normatives

Flow vs current at different pressure drops

Oil temperature

-40 - +120°C

37.9/10.0 34.1/9.0 30.3/8.0 26.5/7.0 22.7/6.0 18.9/5.0 15.2/4.0 11.4/3.0

Filtration

10 ÷ 25 µ

104 bar 1500 psi

Tightening torque

30Nm

207 bar 3000 psi

35 bar 500 psi

Pressure Drop 2 > 1 with fully open valve

3.4/50 6.9/100 10.3/150 13.8/200 17.2/250 20.7/300 24.1/350 27.6/400 31.0/450

17 bar 250 psi

Flow [l/min] [gpm]

7.6/2.0 3.8/1.0 0

P [bar]/[psi]

0,9 100 % of max I

0,1 20 0,2

0,3 40 0,6

0,5 60 1,0

0,7 80 1,4

I [A] coil 12DC I [A] coil 24DC

1,8

Q [l/min] [gpm]

7.6 2

15.1 4

22.7 6

30.3 8

Note: Values measured on valve alone (no cavity) with an oil viscosity of 46 cSt at 50 °C. Pressure drop may change depending on fluid viscosity and temperature.

Made with FlippingBook Online newsletter creator