Hydronit Catalogue

PPC 2017/1-D150

www.hydronit.com +39 03621841210

SECTION D

VMPC2 - PROPORTIONAL PRESSURE RELIEF VALVE

113

Hex. 20

2

59

1

Coils

ø 38

Supply Voltage Coil code

Connector code

12DC 24DC

98001190 KA132000B1 98002190 KA132000B1

27

89

For the controller see the VPC table in D section

3/4-16 UNF-2B

Spare part code

Assembly code

1

2

Direct acting proportional relief valve

VMPC

P*** Voltage

where *** stands for max setting pressure [bar]. eg. P25012DC

Nominal size: 2 = 2 l/min

Main features

2

Max pressure

Working range: A = 2 ÷ 80 bar C = 4 ÷ 250 bar Options: E = emergency (std)

350 bar

C

Mounting cavities

Max flow

2l/min

E

Weight

0,46 Kg

0 1 2 5 6 7 8 3 4

PWM

120Hz

Supply voltage: - 0000 = no coil - 12DC - 24DC see coils table

Hysteresis

5%

0000

Duty cycle

ED 100%

Note: cavities 3, 4 and 6 are present on central manifold type UB only.

Voltage

+/- 10% nominal voltage

EN50081-1/EN50082-2(89/336 CEE electr. comp.) - 73/23/CEE / 96/68/CEE (low voltage)

Normatives

Pressure drop diagram

Pressure vs current

Note: Supplying current to the coil from 0 to I max (see diagram), a proportional pressure variation is obtained on port P. For the controller see table D170 Recommended tightening torque: 25Nm Recommended filtration: 25 ÷ 50 µ Oil temperature: -30 ÷ + 80 °C

18

300

15

250

C

C

12

200

9

Pressure [bar] 150

Pressure [bar]

A

6

100

A

3

50

0

0,4 0,8

0,8 1,6

1 2

0,2 0,4

0,6 1,2

0 0

24V DC 12V DC

1 2 3 4 5

Note: Values measured on valve alone (no cavity) with an oil viscosity of 46 cSt at 50 °C. Pressure drop may change depending on fluid viscosity and temperature.

Flow [l/min]

Current [A]

Made with FlippingBook Online newsletter creator