Problem

Hypothetical Cause

Resolution

Broken tank O-ring, drain plug not tightened, damaged or non-compliant tank

1) Check the condition of the central body o-ring 2) Check the tightening torques of the caps 3) If the above points are compliant, replace the tank

The tank is leaking oil

9

1) Check the condition of the pump suction pipe, whether it is correctly assembled and whether it is always below the minimum fluid level. 2) Check the pump O-rings. If damaged, replace them. If there is dirt, clean them and provide a suitable filter in the circuit.

Damaged or non-under head suction pipe, clogged valve

The hand pump does not draw fluid

10

Please note that adopting some of the behaviours and solutions proposed in the table could result in the warranty being voided. For further details, please see the warranty terms and conditions or contact customer service.