Hydronit Catalogue

PPC 2017/1-D100

www.hydronit.com +39 03621841210

SECTION D

CM - MANUAL LEVER VALVE

Motor switch off, valve closed

Open valve

Motor switch on

30°

250

+

-

Micro switch

- +

4xM5

63,5

3/4-16 UNF-2A

ø12,7

1

Starting switch

Connection example

Optional Micro switch

M

2

37

26

29

58

Spare part code

Assembly code

CM04L

CM04M

2

2

E (CM04L) EM (CM04M)

CM

Two-way manual lever valve Nominal size: 04 = 3/4-16 UNF

1

1

Main features

04

Mounting cavities

Max pressure

300 bar 25 l/min 0,34 kg

Max flow

Type:

Weight

L

L = lever (std) M = lever+micro switch

Max current Protection

10 A - 400 V IP20 (up to IP65 on request) -25°C ÷ + 85°C (higher temperature on request)

0 1 2 5 6 7 8 3 4

Room temp.

Note: cavities 3, 4 and 6 are present on central manifold type UB only.

Fixing bolts: 4 x M5x45 (torque 5Nm) Cartridge tightening torque: 25Nm Recommended filtration: 25 ÷ 50 µ Oil temperature: -30 ÷ + 80 °C

Pressure drop diagram

Micro switch option

Plastic terminal cover protection

10 12

P [bar] 4 2 0 6 8

1 2

2 1

38

49,2 25,4

5

10

15

20

25

Spare part code MCR1222

Spare part code VFC02

Flow [l / min]

Note: Values measured on valve alone (no cavity) with an oil viscosity of 46 cSt at 50 °C. Pressure drop may change depending on fluid viscosity and temperature

Made with FlippingBook Online newsletter creator