Hydronit Catalogue
PPC 2017/1-D010
www.hydronit.com +39 03621841210
SECTION D
VMDC20 - DIRECT ACTING MAIN RELIEF VALVE
35,5 Max 53,5
IMPROVED
33,5
P
ø 12,7
3/4-16UNF
T
Hex. 3
Hex. 24
Hex. 13
Hex. 10
20
19
20
M6
Option 2
Option 3
Option 4
Ø 20,5
24
18,5
39,5
M6
Assembly code
Spare part code
P
T
V*** ¨
VMDC
Relief valve
where *** stands for max setting pressure [bar]. Ex. V200
Nominal size: 20 = 20 l/min Working range: A = 3 ÷ 60 bar B = 40 ÷ 120 bar C = 80 ÷ 250 bar D = 150 ÷ 350 bar Option: 1 = M6 screw (std) 2 = handwheel 3 = with cap 4 = plastic seal
20
Main features
where is the option ¨
Max pressure
350 bar 20 l/min 0,14 kg
B
Max flow
Weight
Mounting cavities
0 1 2 5 6 7 8 3 4
Recommended tightening torque: 40 Nm Recommended filtration: 25 ÷ 50 µ Oil temperature: -30 ÷ + 80 °C
1
Note: cavities 3, 4 and 6 are present on central manifold type UB only.
Pressure vs Flow
Minimum setting pressure
180
420
D
P [bar] 150
P [bar] 350
D
120
280
C
C
90
210
B A
60
140
B
30
70
A
0
0
4 8 12 16 20
4 8 12 16 20
Flow [l / min]
Flow [l / min]
Note: Values measured on valve alone (no cavity) with an oil viscosity of 46 cSt at 50 °C. Pressure drop may change depending on fluid viscosity and temperature
Made with FlippingBook Online newsletter creator