Hydronit Catalogue
PPC 2017/1-F100
www.hydronit.com +39 03621841210
SECTION F
NG6 (CETOP 3) SANDWICH MODULAR MANIFOLD FOR SAE08 CARTRIDGE VALVES
ASSEMBLY CODE - example
Cavity 1
Cavity 2 A24DC -
D24DC -
E60433000
Cavity 2: See component codes below
2 cavity block
Dimensions in mm (inches)
Cavity 1: See component codes below
Main features
Max pressure
300 bar
Max flow
up to 40 l/min 0,4 Kg (0,88lb)
Weight
1
2
4 M5x ** bolts . 5Nm torque 10,9 class steel or above
Fixing bolts
Fluid temperature Filtration degree
-20 ÷ +80°C
25 ÷ 50 µ
45 (1,77) 40 (1,57)
90 (3,54)
Application example
E60433000 Spare part code
3/4-16 UNF
T
A B
1
2
P T
B A
Hydraulic scheme
P 1 T 1
B 1
A 1
P
2
1
N°4 holes Ø5,5
A P B T
D
D
MDV30E
MDV30E
C
C
MSV31E
MSV31E
AR
AR
MSVR30
MSVR30
1
2
T
T
CSPC15
CSPC15
L
L
E70100004
E70100004
N
N
E70100002
E70100002
Note: to add external manifolds to PPC assembly code, just add their spare part codes at the end of the PPC code. Example: PPC-0,8 12DC-UA-G1,1-J-V200-G-RETURN KIT-1,5L+E60403010+ E60433000+MDV30E000+24DC_M630+MSV300000+24DC_M630+SD03C2 +2x24DC_M160. For more info and for a mounting example, please see E60433001 code (NG6 CETOP 3 flow control sandwich valve) in G section. The Cetop valve attachment is on the motor side. With AC motor frames bigger than 71 and DC motors bigger than dia. 125, always add a spacer manifold (see E60403004 code in F section) below the modular block to avoid interference between the valve and the motor.